Difference between revisions of "Notification pattern communication diagram"
Jump to navigation
Jump to search
Hugo.berdon (talk | contribs) (Created blank page) |
Hugo.berdon (talk | contribs) |
||
Line 1: | Line 1: | ||
+ | [[File:Comm diag it2 ALL v3.5-Notification.drawio.png|center|thumb|930x930px]] | ||
+ | == Make notification == | ||
+ | |||
+ | * ''Description'': Data Owner sends a message to the Connector DT with the notification. Data Evaluator and Data Owner identify both components. | ||
+ | |||
+ | * ''Message type'': Specified in ‘Data Dictionary’. | ||
+ | |||
+ | |||
+ | '''Error handling''' | ||
+ | |||
+ | * If Connector DT cannot be reached there will be a communication error. [10503] | ||
+ | * Mandatory fields must be present in the request. [40502] | ||
+ | |||
+ | == SMP addressing == | ||
+ | |||
+ | * ''Description:'' Connector DT sends a request to the SML to get the SMP address. Data Evaluator identifier will be sent as the participant identifier. Detailed information is available in ‘[https://ec.europa.eu/cefdigital/wiki/display/CEFDIGITAL/eDelivery+SMP+-+1.10 eDelivery SMP]’. | ||
+ | |||
+ | == Node information == | ||
+ | '''Request''' | ||
+ | |||
+ | * ''Description:'' Connector DT sends a request to the SMP to get gateway information. Multi evidence approach is available in ‘SMP query process in DE4A’ Document. 2 | ||
+ | |||
+ | * ''Message type:'' Detailed in ‘eDelivery usage in DE4A’ Document. 5 | ||
+ | |||
+ | |||
+ | '''Response''' | ||
+ | |||
+ | * ''Description:'' SMP sends a response to Connector DT providing the gateway information. The destination endpoint and the certificate will be provided. | ||
+ | |||
+ | * ''Message type:'' Detailed in ‘eDelivery usage in DE4A’ Document. 5 | ||
+ | |||
+ | |||
+ | '''Error handling''' | ||
+ | |||
+ | * If SMP cannot be reached there will be a communication error [10403]. | ||
+ | |||
+ | * Mandatory fields must be present in the request. [40402] | ||
+ | * If request information does not obtain results, there will be a no data found error. [40406] | ||
+ | |||
+ | Detailed information is available in ‘[https://ec.europa.eu/cefdigital/wiki/display/CEFDIGITAL/eDelivery+BDXL+1.6 eDelivery BDXL]’. | ||
+ | |||
+ | == Send notification == | ||
+ | |||
+ | * ''Description:'' The Connector DT sends a message to the Connector DR with the notification. Same message as step 1. | ||
+ | |||
+ | * ''Message type:'' Specified in ‘Data Dictionary’ Document. 6 | ||
+ | |||
+ | '''Error handling''' | ||
+ | |||
+ | * If Connector DR cannot be reached there will be a communication error. [10403] | ||
+ | * Mandatory fields must be present in the request. [40402] | ||
+ | |||
+ | == Forward notification == | ||
+ | |||
+ | * ''Description:'' Connector DR sends a message to the Data Evaluator with the notification. Same message as step 1. | ||
+ | |||
+ | * ''Message type:'' Specified in ‘Data Dictionary’ Document. 6 | ||
+ | |||
+ | '''Error handling''' | ||
+ | |||
+ | * If Data Evaluator cannot be reached there will be a communication error. [10303] | ||
+ | * Mandatory fields must be present in the request. [40302] |
Revision as of 11:11, 4 May 2022
Make notification
- Description: Data Owner sends a message to the Connector DT with the notification. Data Evaluator and Data Owner identify both components.
- Message type: Specified in ‘Data Dictionary’.
Error handling
- If Connector DT cannot be reached there will be a communication error. [10503]
- Mandatory fields must be present in the request. [40502]
SMP addressing
- Description: Connector DT sends a request to the SML to get the SMP address. Data Evaluator identifier will be sent as the participant identifier. Detailed information is available in ‘eDelivery SMP’.
Node information
Request
- Description: Connector DT sends a request to the SMP to get gateway information. Multi evidence approach is available in ‘SMP query process in DE4A’ Document. 2
- Message type: Detailed in ‘eDelivery usage in DE4A’ Document. 5
Response
- Description: SMP sends a response to Connector DT providing the gateway information. The destination endpoint and the certificate will be provided.
- Message type: Detailed in ‘eDelivery usage in DE4A’ Document. 5
Error handling
- If SMP cannot be reached there will be a communication error [10403].
- Mandatory fields must be present in the request. [40402]
- If request information does not obtain results, there will be a no data found error. [40406]
Detailed information is available in ‘eDelivery BDXL’.
Send notification
- Description: The Connector DT sends a message to the Connector DR with the notification. Same message as step 1.
- Message type: Specified in ‘Data Dictionary’ Document. 6
Error handling
- If Connector DR cannot be reached there will be a communication error. [10403]
- Mandatory fields must be present in the request. [40402]
Forward notification
- Description: Connector DR sends a message to the Data Evaluator with the notification. Same message as step 1.
- Message type: Specified in ‘Data Dictionary’ Document. 6
Error handling
- If Data Evaluator cannot be reached there will be a communication error. [10303]